A
complete range of GRP preformed roof trims and sections suitable
for all liquid applied polymeric and single membrane systems. Our
unique high adhesion finish gives excellent adhesion to most liquid
applied systems without the need for priming. (Tested with both
rigid and flexible polyester, polyurethane, acrylic and alkyd systems.)
Suitable for flat roofing, pitched roofing, cladding, domestic and
industrial applications.
|
- Consistent
Weight and Thickness
|
- Facilitates
Roof Void Ventilation
|
|
|
- Unique
High Adhesion Finish
|
- Choice
of Laminate Weight and Thickness
|
- Fire
Retardent (BS 476 Part 3)
|
- Excellent
Finished Appearance
|
|
|
|
- U.V.
Stabilized and Prepigmented
|
| Section |
Code |
Description |
Application |
 |
A200 |
Drip
Facia
200mm
girth
90mm
deep facia
|
Fitted
to roof edge for drainage into gutter. All edge detailing where drainage
is required. |
 |
A250 |
Drip
Facia
250mm
girth
140mm
deep facia
|
Roof
edge detail to cover insulation. Deep facia to allow gutter penetration. |
 |
B230 |
Raised
edge trim
Check
kerb 230mm girth
105mm
facia depth
|
Flat
roof edge detail to prevent water run off. |
 |
B260 |
Raised
edge trim
260mm
girth
125mm
facia depth
|
Roof
edge detail. Compatible with Universal external covers. |
 |
C100 |
Simulated
lead wall cover flashing
100mm
vertical cover
35mm
wall penetration
|
Replaces
traditional lead flashing. With integral moisture trap return self
secures into brickwork |
 |
C100
std |
Simulated
lead wall cover flashing
100mm
vertical cover
35mm
wall penetration
|
As
above but without integral moisture trap. |
 |
D240 |
Wall
fillet
240mm
girth
90mm
flanges
120mm
upstand height
|
For
use against abutting walls. Gutter lining. Provides expansion joint
and
cross roof ventilation. |
 |
|
Expansion
Joint
280mm
girth
100mm
flanges
50mm
height
|
Expansion
joint for use on large roof areas with rigid systems or to cover existing
ex joints on refurb. May also be used to control roof drainage. |
 |
|
Flat
Flashing
Up
to 1350mm wide
Rolls
from 24m long
300mm
standard width
|
Flat
section for use as continuous flashing under slates at roof junction.
Gutter lining. |
| Section |
Code |
Description |
Application |
 |
C1 |
Universal
external corner.
Hot
press moulded GRP pre formed corner.
|
For
use with Sections A200 and B260. Provides preformed RH and LH corners. |
 |
C2 |
Fillet
to trim
RH
and LH mouldings.
|
For
use at junction of flat roof and abutting wall. Compatible with sec.
D240, A200, B260. |
 |
C3 |
Fillet
corners
Internal
and external.
|
Chimney
corners. Compatible with D240 only.
|
 |
C4 |
Universal
internal corner.
|
For
use with A200 and B260. |